A measuring unit developed for heavy-duty use on construction sites to measure the thickness of all non-metallic layers in construction, such as bituminous mixtures (asphalt), blast furnace slag, concrete, etc.
The measuring process is non-destructive and approved by TP D-StB 12 (Technical Test Regulations for calculating surface thickness in road construction) for measuring individual and total thickness of layers in road construction.
Using the device in road construction typically involves placing aluminum foil at the bottom of an asphalt layer that has not yet been applied. The foil is embedded within the gravel mixture and does not interfere with the inter-layer bonding process. Decades of experience have shown that the foils do not affect the stability of the asphalt layers.
Unlike the core drilling method, this does not damage the construction layer.
The measuring reflectors can be located via a bar chart display on the measuring unit or acoustically using the included headphones.
Special Probes
- N 100ST: Up to 100 mm for measuring the surface layer in road construction
- N 400ST: Measuring range between 0 and 400 mm for measuring the base and surface layers in road construction
Features
- Non-destructive measurement
- Approved by TP D-StB 12
- Measuring range up to 400 mm
- Direct display of thickness
- Unlimited measurements repeatedly in the same location
- Easy localization of measuring reflectors
Specifications
Measuring Principle | Eddy current testing | |
Measurable Layers | All non-metallic road layer materials | |
Reflectors |
Aluminum foils or plates of different sizes |
|
Measuring Range |
0 … 40 cm N400ST standard probe |
|
Resolution | 0.1 cm: | 0 … 30 cm |
0.2 cm: | 30 … 35 cm | |
0.4 cm: | 35 … 40 cm | |
Tolerance of Standard Probe |
Reflectors: 0.7 m x 0.3 m · 1.0 m x 0.3 m |
|
Reflectors: 0.6 m x 0.6 m · 1.0 m x 1.0 m steel 0 … 30 Measuring Range / (cm) : ± (0.1 cm +2 % of reading) 30 … 35 Measuring Range / (cm) : ± 2 % of reading 35 … 40 Measuring Range / (cm) : ± 2 % of reading |
||
Display | Digital LCD | |
Data Memory |
DIRECT mode: approx. 500 single measurements and statistical values |
|
Power Supply | 1 x 9 V alkaline battery | |
Battery Life | ~ 20 hours | |
Ambient Temperature | Measuring unit: 0 °C - 50 °C | Probe: 0 °C - 70 °C |
Title | Type | Size | Download |
---|---|---|---|
StratoTest-4100_en_937-A2.pdf | 1.45MB | Download |