Expand the illuminated area with a compatible Extension
GX Orion 2.0 Extension expands the illuminated area of a GX Orion 2.0 system.
An Extension cannot operate on its own: it must connect to a compatible Master.
10
UV-A LEDs per Extension
Choose the right variant
Match both the beam profile and light type to the Master; Remote models use the corresponding UV & WH Extension.
Beam area is specified above 1,000 µW/cm². Flood and Mid are measured at 38.1 cm; Spot at 60 cm.
On mobile, scroll the table horizontally.
| Part no. |
Beam / light type |
UV irradiance (µW/cm²) |
Measurement distance (cm) |
Beam area (cm) |
Weight (kg) |
| L4005 |
Spot / UV + white light |
> 12 000 |
60 |
41 × 35 |
2.7 |
| L4006 |
Mid / UV + white light |
9 000 |
38.1 |
45 × 38 |
2.7 |
| L4007 |
Flood / UV + white light |
4 500 |
38.1 |
54 × 38 |
2.7 |
| L4008 |
Flood / UV-A only |
4 500 |
38.1 |
54 × 38 |
2.7 |
UV = UV-A only. WH = white light. Remote Master models use the matching UV + WH Extension.
Standards by variant
| Part no. |
Standards / specifications |
| L4005 |
ASTM E3022, ISO 3059 |
| L4006 |
ASTM E3022, ISO 3059, Pratt & Whitney |
| L4007 |
ASTM E3022, ISO 3059, RRES 90061, Pratt & Whitney |
| L4008 |
ASTM E3022, ISO 3059, RRES 90061, Pratt & Whitney, Airbus AITM6-1001, USAF, Boeing |
Check the selected model’s certificate against your inspection procedure requirements.
Expansion and compatibility
Powered through a compatible Master/Extension system; cannot operate alone.
| GX Orion 2.0 Master |
Matching Extension |
| L4000 |
L4005 Spot UV & WH |
| L4001 / L4002 |
L4006 Mid UV & WH |
| L4003 |
L4007 Flood UV & WH |
| L4004 |
L4008 Flood UV |
One PSU powers a maximum of three lamp modules in a Master/Extension system. Match both beam profile and light type as shown in the table. Custom cable lengths are available. Contact us about larger installations or connection to an existing GX Orion installation.